			 Series 
			 | 
		
		
			| 
			 01 
			 | 
			
			 Pilot control valve for external electronics 
			 | 
			
			 VT-DFP 
			 | 
		
		
			| 
			 Pilot control valve with integrated analog electronics 
			 | 
			
			 VT-DFPE 
			 | 
		
		
			| 
			 Pilot control valve with integrated digital electronics (CANopen fieldbus) 
			 | 
			
			 VT-DFPC 1) 
			 | 
		
		
			| 
			 Pilot control valve with integrated digital electronics, variable-speed 
			 | 
			
			 VT-DFPn 1) 
			 | 
		
		
			| 
			 Pilot control valve with integrated digital electronics (ethernet-based bus systems) 
			 | 
			
			 VT-DFPD 
			 | 
		
		
			| 
			 Pilot control valve with integrated digital electronics (ethernet-based bus systems) 
			 | 
			
			 VT-DFPF 
			 | 
		
		
			| 
			 Control spool design 
			 | 
		
		
			| 
			 02 
			 | 
			
			 Standard 
			 | 
			
			 A 
			 | 
		
		
			| 
			 2-groove (only for replacement requirement) 
			 | 
			
			 B 
			 | 
		
		
			| 
			 4-groove (e.g. for HFC fluids) 
			 | 
			
			 C 
			 | 
		
		
			| 
			 03 
			 | 
			
			 Component series 10 ... 19 (10 ... 19: unchanged installation and connection dimensions); only type VT-DFPD and VT-DFPF 
			 | 
			
			 1X 
			 | 
		
		
			| 
			 Component series 20 … 29 (20 … 29: unchanged installation and connection dimensions) 
			 | 
			
			 2X 
			 | 
		
		
			| 
			 04 
			 | 
			
			 Direct voltage 24 V 
			 | 
			
			 G24 
			 | 
		
		
			| 
			 05 
			 | 
			
			 Connector (without mating connector) 
			 | 
			
			 K0 2) 
			 | 
		
		
			| 
			 Installation orientation connector (VT-DFP) and/or integrated electronics (see below and "Dimensions") 
			 | 
		
		
			| 
			 06 
			 | 
			
			 Radially to the pump axis 
			 | 
			
			 0 
			 | 
		
		
			| 
			 folded 90° in the direction of the subplate with counterclockwise direction of rotation 
			 | 
			
			 1 
			 | 
		
		
			| 
			 folded 90° in the direction of the subplate with clockwise direction of rotation 
			 | 
			
			 2 
			 | 
		
		
			| 
			 Additional functions: Closed-loop control 
			 | 
		
		
			| 
			 07 
			 | 
			
			 – VT-DFP 
			 | 
			
			 no code 
			 | 
		
		
			| 
			 – VT-DFPE 
			 | 
		
		
			| 
			 Switchable pressure controller (high signal) 
			 | 
			
			 A 
			 | 
		
		
			| 
			 Power limitation adjustable at the OBE valve 
			 | 
			
			 B 
			 | 
		
		
			| 
			 Power limitation adjustable via analog input 
			 | 
			
			 C 
			 | 
		
		
			| 
			 Pressure controller that can be switched off (high signal) 
			 | 
			
			 D 
			 | 
		
		
			| 
			 – VT-DFPC 
			 | 
		
		
			| 
			 Standard 
			 | 
			
			 A 
			 | 
		
		
			| 
			 – VT-DFPn 
			 | 
		
		
			| 
			 Teach-in version for cyclic operation 
			 | 
			
			 A 
			 | 
		
		
			| 
			 Real-time version (speed calculation without teach-in) 
			 | 
			
			 R 
			 | 
		
		
			| 
			 – VT-DFPD 
			 | 
		
		
			| 
			 Standard 
			 | 
			
			 A 
			 | 
		
		
			| 
			 For variable-speed operation 
			 | 
			
			 N 
			 | 
		
		
			| 
			 – VT-DFPF 
			 | 
		
		
			| 
			 Standard 
			 | 
			
			 A 
			 | 
		
		
			| 
			 Electronics assembly 
			 | 
		
		
			| 
			 08 
			 | 
			
			 – VT-DFP 
			 | 
			
			 no code 
			 | 
		
		
			| 
			 – VT-DFPE 
			 | 
		
		
			| 
			 Standard electronics with leakage oil compensation 
			 | 
			
			 0 
			 | 
		
		
			| 
			 Standard electronics without leakage oil compensation 
			 | 
			
			 1 
			 | 
		
		
			| 
			 – VT-DFPC 
			 | 
		
		
			| 
			 Standard 
			 | 
			
			 0 
			 | 
		
		
			| 
			 – VT-DFPn 
			 | 
		
		
			| 
			 Standard 
			 | 
			
			 0 
			 | 
		
		
			| 
			 – VT-DFPD, VT-DFPF 
			 | 
		
		
			| 
			 Bus system: Sercos III 
			 | 
			
			 S 
			 | 
		
		
			| 
			 Bus system: CANopen over EtherSAAR 
			 | 
			
			 T 
			 | 
		
		
			| 
			 Bus system: servo drive over EtherSAAR 
			 | 
			
			 D 
			 | 
		
		
			| 
			 Bus system: Servodrive over Varan 
			 | 
			
			 V 
			 | 
		
		
			| 
			 Bus system: Ethernet/IP 
			 | 
			
			 E 
			 | 
		
		
			| 
			 Bus system: PROFINET RT 
			 | 
			
			 N 
			 | 
		
		
			| 
			 Bus system: Powerlink 
			 | 
			
			 W 4) 
			 | 
		
		
			| 
			 Actual pressure value input (see "Electrical connections") 
			 | 
		
		
			| 
			 09 
			 | 
			
			 – VT-DFP 
			 | 
			
			 no code 
			 | 
		
		
			| 
			 – VT-DFPE, VT-DFPC, VT-DFPn 
			 | 
		
		
			| 
			 Current input 4 … 20 mA 
			 | 
			
			 Port X1 
			 | 
			
			 C 
			 | 
		
		
			| 
			 Voltage input 0...10 V (standard) 
			 | 
			
			 Port X1 
			 | 
			
			 V 
			 | 
		
		
			| 
			 Voltage input 1 … 10 V 
			 | 
			
			 Port X1 
			 | 
			
			 E 
			 | 
		
		
			| 
			 Voltage input 0.5...5 V (standard) 
			 | 
			
			 Connection X2 
			 | 
			
			 F 
			 | 
		
		
			| 
			 – VT-DFPD 
			 | 
		
		
			| 
			 Voltage input 0 ... 10 V (freely configurable, parameter setting on delivery) 
			 | 
			
			 Port XH4 
			 | 
			
			 V 
			 | 
		
		
			| 
			 Voltage input 0.5 ... 5 V (freely configurable, parameter setting on delivery) 
			 | 
			
			 Port X2M1 
			 | 
			
			 F 
			 | 
		
		
			| 
			 – VT-DFPF 
			 | 
		
		
			| 
			 Voltage input 0 ... 10 V (freely configurable, parameter setting on delivery) 
			 | 
			
			 Port XH1 
			 | 
			
			 V 
			 | 
		
		
			| 
			 Voltage input 0.5 ... 5 V (freely configurable, parameter setting on delivery) 
			 | 
			
			 Port X2N 
			 | 
			
			 F 
			 | 
		
		
			| 
			 Seal material (observe compatibility of seals with hydraulic fluid used, see "Technical data") 
			 | 
		
		
			| 
			 10 
			 | 
			
			 FKM seals 
			 | 
			
			 V 
			 | 
		
		
			| 
			 11 
			 | 
			